CLI Tool Reference

The damiao command-line tool provides a unified interface for scanning, configuring, and controlling DaMiao motors.

Installation

After installing the package, the damiao command will be available in your PATH:

pip install damiao-motor

Getting Help

To see all available commands:

damiao --help

To get help for a specific command:

damiao <command> --help

Commands

scan

Scan for connected motors on the CAN bus.

damiao scan [OPTIONS]

Options:

Option Type Description
--ids ID [ID ...] Motor IDs to test (e.g., --ids 1 2 3). If not specified, tests IDs 0x01-0x10.
--duration FLOAT Duration to listen for responses in seconds (default: 0.5)
--debug flag Print all raw CAN messages for debugging
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000)

Examples:

# Scan default ID range (0x01-0x10)
damiao scan

# Scan specific motor IDs
damiao scan --ids 1 2 3

# Scan with longer listen duration
damiao scan --duration 2.0

# Scan with debug output
damiao scan --debug

send-cmd

Send command to motor with specified control mode. Loops continuously until Ctrl+C.

damiao send-cmd [OPTIONS]

Options:

Option Type Description
--id INT Motor ID (required)
--mode {MIT,position_velocity,velocity,force_position_hybrid} Control mode (default: MIT)
--position FLOAT Desired position (radians). Required for MIT, position_velocity, force_position_hybrid modes.
--velocity FLOAT Desired velocity (rad/s). Required for MIT, position_velocity, velocity modes.
--stiffness FLOAT Stiffness (kp) for MIT mode (default: 0.0)
--damping FLOAT Damping (kd) for MIT mode (default: 0.0)
--feedforward-torque FLOAT Feedforward torque for MIT mode (default: 0.0)
--velocity-limit FLOAT Velocity limit (rad/s, 0-100) for force_position_hybrid mode
--current-limit FLOAT Torque current limit normalized (0.0-1.0) for force_position_hybrid mode
--frequency FLOAT Command frequency in Hz (default: 100.0)
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000)

Examples:

# MIT mode (default)
damiao send-cmd --id 1 --mode MIT --position 1.5 --velocity 0.0 --stiffness 3.0 --damping 0.5

# Position-Velocity mode
damiao send-cmd --id 1 --mode position_velocity --position 1.5 --velocity 2.0

# Velocity mode
damiao send-cmd --id 1 --mode velocity --velocity 3.0

# Force-Position Hybrid mode
damiao send-cmd --id 1 --mode force_position_hybrid --position 1.5 --velocity-limit 50.0 --current-limit 0.8

# With custom frequency
damiao send-cmd --id 1 --mode MIT --position 1.5 --frequency 50.0

set-zero-command

Send zero command to a motor (pos=0, vel=0, torq=0, kp=0, kd=0). Loops continuously until Ctrl+C.

damiao set-zero-command [OPTIONS]

Options:

Option Type Description
--id INT Motor ID to send zero command to (required)
--frequency FLOAT Command frequency in Hz (default: 100.0)
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000)

Examples:

# Send zero command continuously
damiao set-zero-command --id 1

# With custom frequency
damiao set-zero-command --id 1 --frequency 50.0

set-zero-position

Set the current output shaft position to zero.

damiao set-zero-position [OPTIONS]

Options:

Option Type Description
--id INT Motor ID (required)
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000)

Examples:

# Set current position to zero
damiao set-zero-position --id 1

set-can-timeout

Set CAN timeout alarm time (register 9).

damiao set-can-timeout [OPTIONS]

Options:

Option Type Description
--id INT Motor ID (required)
--timeout INT Timeout in milliseconds (ms) (required)
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000)

Examples:

# Set CAN timeout to 1000 ms
damiao set-can-timeout --id 1 --timeout 1000

set-motor-id

Change the motor's receive ID (ESC_ID, register 8). This is the ID used to send commands to the motor.

damiao set-motor-id [OPTIONS]

Options:

Option Type Description
--current INT Current motor ID (to connect to the motor) (required)
--target INT Target motor ID (new receive ID) (required)
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000)

Examples:

# Change motor ID from 1 to 2
damiao set-motor-id --current 1 --target 2

Note

After changing the motor ID, you will need to use the new ID to communicate with the motor.

set-feedback-id

Change the motor's feedback ID (MST_ID, register 7). This is the ID used to identify feedback messages from the motor.

damiao set-feedback-id [OPTIONS]

Options:

Option Type Description
--current INT Current motor ID (to connect to the motor) (required)
--target INT Target feedback ID (new MST_ID) (required)
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000)

Examples:

# Change feedback ID to 3 (using motor ID 1 to connect)
damiao set-feedback-id --current 1 --target 3

Note

The motor will now respond with feedback using the new feedback ID.

gui

Launch the web-based GUI for viewing and controlling DaMiao motors.

damiao gui [OPTIONS]

Options:

Option Type Description
--host STR Host to bind to (default: 127.0.0.1)
--port INT Port to bind to (default: 5000)
--debug flag Enable debug mode
--production flag Use production WSGI server (requires waitress)

Examples:

# Start GUI on default host and port (http://127.0.0.1:5000)
damiao gui

# Start GUI on custom port
damiao gui --port 8080

# Start GUI on all interfaces
damiao gui --host 0.0.0.0

# Start GUI with production server
damiao gui --production

Backward Compatibility

The damiao-gui command is still available as an alias for backward compatibility, but damiao gui is the recommended way to launch the GUI.

Global Options

All commands support the following global options:

Option Type Description
--channel STR CAN channel (default: can0)
--bustype STR CAN bus type (default: socketcan)
--bitrate INT CAN bitrate in bits per second (default: 1000000). Only used when bringing up interface.

These options can be specified either before or after the subcommand:

damiao --channel can1 scan
damiao scan --channel can1

Control Modes

The send-cmd command supports multiple control modes:

MIT Mode (Default)

MIT-style control mode with position, velocity, stiffness (kp), damping (kd), and feedforward torque.

  • CAN ID: motor_id
  • Parameters: position, velocity, stiffness, damping, feedforward_torque

Position-Velocity Mode

Position-velocity control mode for trapezoidal motion profiles.

  • CAN ID: 0x100 + motor_id
  • Parameters: position, velocity (maximum velocity during acceleration)

Velocity Mode

Velocity control mode.

  • CAN ID: 0x200 + motor_id
  • Parameters: velocity

Force-Position Hybrid Mode

Hybrid control mode combining position control with velocity and current limits.

  • CAN ID: 0x300 + motor_id
  • Parameters: position, velocity_limit (0-100 rad/s), current_limit (0.0-1.0 normalized)

Real-time Feedback

All looping send commands (send-cmd, set-zero-command) continuously print motor state information:

State: 1 (ENABLED) | Pos:   1.234 rad | Vel:   0.567 rad/s | Torq:   0.123 Nm | T_mos: 45.0°C | T_rotor: 50.0°C

The state information includes: - State: Status code and human-readable status name - Pos: Current position (radians) - Vel: Current velocity (rad/s) - Torq: Current torque (Nm) - T_mos: MOSFET temperature (°C) - T_rotor: Rotor temperature (°C)

Safety Notes

Safety First

  • Always ensure motors are securely mounted before sending commands
  • Start with zero commands or low values to verify motor response
  • Monitor motor temperatures during operation
  • Use Ctrl+C to stop looping commands immediately
  • Test in a safe environment before production use